| Building
Wires |
|
TW
Wire (Thermoplastic Moisture-Resistant Wire)
Used as interior housewiring at circuit voltage
up to 600 volts. Maximum operating temperature
is 60°C in dry or wet application. |
 |
|
|
THW
Wire (Thermoplastic Heat-and Moisture-Resistant
Wire)
Used as interior housewiring at circuit voltage
up to 600 volts. Maximum operating temperature
is 75°C in dry or wet application.
|
 |
|
THHN/THWN (Thermoplastic Heat-Resistant Wire with
Nylon Jacket)
A general purpose 600 volt building wire that can
be used as a power, lighting and control wiring.
Maximum operating temperature is 90°C for dry
application and 75°C for wet application. |
 |
|
Durex Wire (Type NM) Non-Metallic Sheathed Cable
Designed specifically for use as an internal 600
volts building wire installed above ground and in
any location at maximum operating temperature of
60°C. Use of conduit is optional as per section
5.5.4 of the Philippine Electrical Code. |
 |
|
TF Wire (Thermoplastic Fixture)
Used as lighting fixture or interior appliance wire
in circuits not exceeding 600 volts at a maximum
operating temperature of 60°C in dry or wet
location. |
 |
|
TFN (Thermoplastic Fixture) Wire with Nylon Jacket
Used as lighting fixture, interior appliance wire,
machine tool wire or hook up wire in circuits not
exceeding 600 volts at a maximum operating temperature
of 90°C in dry application and 75°C in wet
location. |
 |
| |
|
| Aluminum
Wires |
Bare All Aluminum Conductor (AAC)
Used for overhead transmission and distribution
of electric power. |
 |
|
Bare
Aluminum Conductor Steel Reinforced (ACSR)
Used for power transmission or distribution line.
For multiflexed cable, it is used as uninsulated
neutral support or messenger wire. |
 |
|
PE Covered All Aluminum Conductor (AAC)
Used as secondary service drop wires, 600 volts
phase to phase from a utility's distribution line
of user's attachment point. Also, it may be applied
as a transmission or distribution line and is installed
aerially. |
 |
|
PE Covered Aluminum Conductor Steel Reinforced (ACSR)
Used as power transmission or distribution line.
For multiflexed cable, it is used as uninsulated
neutral support or messenger wire. |
 |
| |
|
| Communication
Cables |
Standard Aerial Telephone Cable (SATC)
Used for telecommunication system and is either
applied aerially or in duct. Manufacturing requirement
of this type of cable is according to REA PE-22
specifications. |
 |
|
Direct
Burial Telephone Cable (DBTC)
Used for telecommunication system and is intended
for underground and direct burial application. Manufacturing
requirements of this type of cable is according
to REA PE-23 specifications. |
 |
|
Jelly-Filled Telephone Cable (JFTC)
Used for telecommunication system and is intended
for underground and direct burial application. Manufacturing
requirements of this type of cable is according
to REA PE-39 specifications. |
 |
|
Foam Skin-Filled Telephone Cable (FSF)
Used for telecommunication system and is intended
for direct burial, underground, and aerial application.
Manufacturing requirement of this type of cable
is according to REA PE-89 specifications. |
 |
|
Intercom Cable
Used as an internal wiring in an intercom network
system at maximum conductor temperature of 60°C. |
 |
|
Telephone Dropwire
Used to transmit signal from a utility's source
to the user's attachment point at maximum operating
temperature of 75°C. |
 |
|
Jacketed Interior Wire
Used as a distribution line between a protector
and a telephone connector of a subscriber's line
at a maximum operating temperature of 60°C. |
 |
| |
|
| Power
Cables |
Durapower Cable 600V
Application of this type of cable is for circuits
rated 600 volts where installation is done in conduits,
trays, troughs, underground ducts and aerial. Maximum
operating is at 75°C. |
 |
|
Durapower Cable 600V (XLPE)
Application of this type of cable is for circuits
rated 600 volts where installation is done in conduits,
trays, troughs, underground ducts and aerial. Maximum
operating is at 90°C. |
.jpg) |
|
Durapower Cable 601-2000V (XLPE)
Application of this type of cable is for circuits
rated 601-2000 volts where installation is done
in conduits, tray, troughs, underground ducts and
aerial. Maximum operating is at 90°C. |
 |
|
Durapower Cable 2001-5000V (XLPE)
Application of this type of cable is for circuits
rated 2001-5000V where installation is done in conduits,
trays, troughs, underground ducts and aerial. Insulation
levels are at 100% and 133%, grounded and ungrounded.
Maximum operating temperature is at 90°C. |
 |
|
Durapower Cable 5001-8000V (XLPE)
Application of this type of cable is for circuits
rated 5001-8000V where installation is done in conduits,
trays, trough, underground ducts and aerial. Insulation
levels are at 100% and 133%, grounded or ungrounded.
Maximum operating temperature is at 90°C. |
 |
|
Durapower Cable 8001-15000V (XLPE)
Application of this type of cable is for circuits
rated 8001-15000V where installation is done in
conduits,trays, trough, underground ducts and aerial.
Insulation levels are at 100% and 133%, grounded
and ungrounded. Maximum operating temperature is
at 90°C. |
 |
| |
|
| Special/Other
Cables: |
Magnet Wire (PVF Class 105°C Round Copper)
Used as windings of electrical equipments such as
motors, generators, transformers, refrigerator compressors,
communication equipment and instruments at a maximum
temperature not exceeding 105°C. |
 |
|
Duracord (Flexible Cord)
Used as portable cable, emergency wire or inside
building wiring in circuits not exceeding 600 volts
and at maximum temperature rating of 60°C. Normally
used in areas where high flexibility is required. |
 |
|
Duplex Cord (Thermoplastic Parallel Cord/SPT)
Used for appliance wiring for circuits not exceeding
300 volts at maximum operation temperature of 60°C. |
 |
|
Submersible Pump Cable
Used to connect electrical circuits of underground
pump cable at 600 volts maximum circuit rating and
75°C maximum conductor thermal rating. |
 |
|
PVC Type Automotive Wire
Used to connect electrical circuits in any automobile
or vehicle. Maximum voltage rating is 50 volts at
maximum conductor temperature of 105°C. |
 |
|
Battery Cable
Used as high temperature wire for electrical connections
of supply (battery) and load in circuits not exceeding
50 volts at maximum operating temperature of 105°C. |
 |
|
Arc Welding Cable
Used for connections from electrode holder and clamp
to arc welder, bus, welding bus or transformer in
shipyards, mines and all hazardous locations. Applicable
to circuits not exceeding 600 volts at 105°C
maximum conductor temperature. |
 |
|
Bare Copper
Suitable for use as overhead transmission and distribution
line. Stranded conductor offers higher flexibility
and may also be applied as uninstalled hook up,
jumper and ground wires in an electrical construction. |
 |
|
Neutral Supported Secondary and Service Dropwire
Used as power distribution line 600 volts phase
to phase from utility's source to the user's attachment
point (service entrance). |
 |
|
Control Cable
Used for control wiring such as for monitoring,
data reading, conveyance of information as in telemetering,
communication, temperature, pressure and flow and
may either be installed aerially, in ducts, conduits,
trays, or directly buried. Also recommended for
application requiring reliability of stable electrical
characteristics under severe service. Maximum circuit
voltage is 600 volts at maximum operating temperature
of 75°C. |
 |
| |
|
| PLP
and Other Merchandise Goods |
PLP
Products - Power
- Big-Grip
Dead-end
- Distribution-Grip
Dead-end
- Guy-Grip
Dead-end
- Service-Grip
Dead-end
- Splice
Conductor
- Full
Tension Splice
- Wrap
Guy Link
- Helical
Rod Spacer
- Spiral
Vibration Damper
- Plastic
Tie
- Distribution
Tie
- Armor
Rod
PLP
Products - For Copper and Fiber Optics
- Splice
Closure - Re-enterable
-
Aerial and Underground
- Splice
Case
- End
Plate Kits
- Power
End Plate Cutter
- Parts
and Accessories
- Bonding
Products
PLP
Products - for ADSS and OPGW Application
- Dielectric
Dead-end for ADSS
- Dielectric
Support for ADSS
- Dielectric
MIDspan Support/Susp
- Dielectric
Suspension for ADSS
- ADSS
Cable Abrasion Protector
- Dead-end
for OPGW
- Suspension
for OPGW
- Formed
Wire Dead-end for OPGW
- Cushion
Clamp for OPGW
-
Repair Rods for OPGW
Other
Merchandise Goods
|

|
Back